Servo Stabilizers
Standard Specification: 3 PHASE AIR COOLED
|
Phase to Phase Input Range
|
245V âââ‰â¬Å 460V AC3Ph
300V -470VAC
340V 480V AC3Ph
360V 480V AC3Ph
|
|
Output Voltage
|
400V/415V AC50Hz
Unbalanced
4 wire : RYB N
|
|
Connections
|
Star
|
|
Operating Frequency
|
47 to 53 Hz
|
|
Output Voltage Adjustable
|
380V to 415V AC in 3Ph
220V to 240V Ac in 1Ph
|
|
Output Voltage Regulation
|
+ 1 %
|
|
(No load to Full Load)
Out Voltage Regulation
|
+ 1 %
|
|
(Full Load) S Correction Rate
|
15V / 20V / 35V / Sec 1Ph
25V / 35V / 60V / Sec 3Ph
|
|
Waveform Distortion
|
Nil
|
|
Output Waveform
|
True Reproduction of Input
|
|
Insulation
|
Class
|
|
Short CKT Period & Percentage
|
300 % for 250 m.sec.
|
|
Normal Operating Temperature
|
00 C to 45 0C
|
|
Climatic Conditions
|
90 % RHMax. Non-Condensing at 350C
|
|
Type of Cooling
|
Natural Air Cooled
|
|
Capacities
|
1) From 0.5 KVA up to 50 KV A 1Phase
2) From 1.5 KVA up to 200 KVA 3phase
|
|
Mode of system
|
Fully Automatic / Manual
|
|
System construction
|
AS PER IS: 9815 OF 1994
|
|
Protection
|
|
Over voltage CUT-OFF
|
(above 245 VAC output)
|
|
Low voltage cut-off
|
(below 200 VAC output)
|
Control CKT protected with fuses spike / lightening arresters (optional)
Overload protected with mcb / mccb
Short CKT protected with HRC fuses
Single phasing preventer: dimmer protection arrangement
Automatic by-pass (optional).
Energy Savings
Better efficiency of 98% achieved by use of prime grade Lamination and electrolytic copper wires of 99.99% purity. Special designs of transformers to minimize losses.
Area of usage
-
Bio-Medical Equipments, C.N.C., Printing & Textile Machinery.
-
Sophisticated Equipment, Split Air Conditioners, Lighting and all areas where regulated voltages are required.
Indication
|
Input ON
|
Input LOW
|
|
Output ON
|
Output CUT-OFF
|
|
Input High
|
Voltmeter
|
Panel controls
Input / output select switch : auto /manual select switch
Increase / decrease spring loaded switch to adjust
The output voltages in manual mode.
Volts adjust to set required out pt voltages in auto mode.
SPECIFICATIONS: SINGLE PHASE SYSTEM
|
Input Voltage Range
|
170 âââ‰â¬Å 270 V AC 50 Hz + 6 %
|
|
Output Voltage
|
230 V AC Nominal
Internally adjustable to 220Vto240V AC
|
|
Output Voltage Regulation
|
+ 1 % of Nominal Voltage
|
|
Average Correction
|
35V / Sec
|
|
Output Voltage Indication
|
Digital Voltmeter
|
|
Accuracy of Digital Voltmeter
|
1 Volt + 0.5 % of full scale + digit
|
|
Resolution of Digital Voltmeter
|
1 Volt
|
|
Electronic Under / Over Voltage
|
UPPER LIMIT 10V+2VAbove Nominal
|
|
Protection
|
LOWER LIMIT 20V+2VBelow Nominal
|
|
Servo Motor Drive
|
Electronic
|
|
Cut-Off
|
Operative above 110 % rated output
Current with graded time delay
|
|
Non-latching LED Operate
|
Input Present
|
|
Indication
|
Output Normal
|
|
Caution
|
Input High
|
|
Cut-off
|
Output High
|
|
Indications
|
Output Low
Output Overload
|
|
Start
|
Press to start (Automatic Optional)
|
|
Resetting Indication (Manual)
|
Through Flashing LED and with intermittent beeper
|
Control Circuit
Micro processor based electronic circuit which will sense all parameter time to time and up-date the system in micro seconds time to give the performance.
|